Precision Plug Capacitor Discharge Tester for Effective Testing
Product Details:
Place of Origin: | China |
Brand Name: | KingPo |
Certification: | Calibration Certificate |
Model Number: | KP-1060 |
Document: | KP -1060 Capacitor Discharg...er.pdf |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 |
---|---|
Price: | To be quoted |
Packaging Details: | safety carton pack or plywood box |
Delivery Time: | 30 working days |
Payment Terms: | T/T |
Supply Ability: | 30 units per month |
Detail Information |
|||
Ventilation Volume: | Constant At (85 ± 1) L / Min | Productivity: | 20-30times/min |
---|---|---|---|
Ready To Ship: | Yes | Quick Delivery: | Yes |
Test Time: | 0-9999s | Dimensions: | 120.5 X 62 X 147.5 Cm |
Mask Test Diameter: | ø25mm | Flow Range: | 0 ~ 150 L / Min |
Bap: | 10 HPa (10 CmH2O) | Quality Assurance: | Yes |
Stable Performance: | Yes | Scanning Depth: | Up To 30 Cm |
Original Manufacturer: | Yes | Technical Support: | Yes |
Host Power Consumption: | <80W | ||
Highlight: | Effective Testing Capacitor Discharge Tester,Precision Plug Capacitor Discharge Tester |
Product Description
Plug capacitor discharge tester
Description
For IEC Testing of residual voltage after plug disconnect.
The KP-1060 disconnects the line at the voltage peak and analyzes results to the requirements of various Standards, allowing quick results.
Scope output for viewing decay waveform.
Presets for IEC 61010-1, IEC62368-1, IEC 60601-1 and IEC60335-1.
Features
Accurate; in accordance with CTL voltage and time specifications.
Disconnects input test voltage at positive or negative peak, normal and reversed polarity
Tests Line-Ground, Line-Neutral and Neutral-Ground.
Micro-controller Technology, one button test, easy setup, LCD display indicates test results.
Ergonomically designed for safety, speed and efficiency.
Designed for product development, production and laboratory use.
Rugged construction that can withstand a 6″ drop with no damage.
Cables, manual and calibration certificate included.
One year warranty.
Technical Parameters:
Minimum/Maximum Test Voltage | 0-300V |
Maximum Test Current | 10A |
Fuse: | 10A, 250V, time delay, 1-¼” x ¼” |
Probe Impedance | > 100MΩ, < 25pF |
AC Peak Detection Accuracy | EUT disconnect within 5% of supply voltage peak |
Test Time Range | 0.50 – 99.0 Seconds |
Test Time Accuracy | ±1% for times ≥ 1 second, +/- 10ms for < 1 second. |
Voltage Setting Resolution | 0.1V |
Voltage Meter Accuracy | ±1.5% of instrument measuring range |
Frequency | 50-60Hz. |
Rated Input Voltage | 220V 50/60HZ |